What are the specifications that the breeding fan needs to abide by during the commissioning process?
If the breeding fan can be debugged according to the standard process, the problems in use will be greatly reduced, but many users cannot follow the strict standard procedures, resulting in various problems in the use of the fan. Then, let's take a look at the specifications that the breeding fan needs to abide by during the commissioning process?
1. It is especially important in the debugging process. The number of people present during the commissioning of the fan shall not be less than two. One person needs to control the power supply of the fan, and the other person should pay attention to observe the various operating conditions of the fan. If any abnormality is found, be sure to notify the person who controls the power supply and immediately stop the machine for a detailed inspection. The machine cannot start running until it is determined that there is no abnormality. The motor power required by the fan means that under certain working conditions, for the centrifugal fan and the fan casing, the power required when the air inlet is fully opened is larger.
2. Check whether the wiring method is consistent with the wiring diagram. Carefully check whether the working voltage of the fan power supply meets the requirements, whether the power supply is out of phase or in the same phase, and whether the capacity of the electrical components meets the requirements. When the fan reaches the normal speed, measure whether the input current of the fan is normal, and the working current of the fan must not exceed its rated current. If the operating current exceeds its rated current, check whether the supply voltage is normal. Fan operation instructions are not complete, but in any case, even if the operation instructions are incomplete, you should have a better understanding of the use of the fan. Each part has detailed operation instructions, users should master it.
3. When testing the livestock fan, close the valve on the inlet and outlet pipes of the fan. After running, gradually open the valve until it reaches the required working state, and pay attention to whether the working current of the fan exceeds the rated current. This is also a good way to use the fan, but there are still some differences in the debugging method for different types of fans of the user. Users pay little attention to their commissioning and assembly.
The developer sells directly, no agency commission, online VR live-action real-time property inspection, safe and reliable
*The information has been encrypted, please feel free to fill in